APC Back-UPS and Smart-UPS with Home Assistant, Synology and NUT
Put your APC UPS on the network with My UPS Pal: no Raspberry Pi, no network card. Here is what we know about APC units.
What to expect
- On our bench
- Back-UPS RS 1000G, Back-UPS ES 600M1 and Smart-UPS X 1500, including real transfers to battery and back.
- From a buyer
- Karl runs My UPS Pal with OLED on a Back-UPS RS 1350MS: “I plugged my UPS in and it detected it in less than a second.” Rated 5 of 5. Read the review.
- Smart-UPS
- Smart-UPS models with an RJ45-style USB port need APC's own USB cable, which comes with the UPS. Some Smart-UPS (
051d:0003) report only charge, runtime and status over HID; where the UPS also offers APC's Modbus over USB, the board reads voltages, load and power from it, once Modbus is enabled in the UPS's front-panel menu (Configuration → Modbus → Enable). The Smart-UPS X 1500 on our bench reads its voltages and load this way. - Deep test
- On the Back-UPS RS 1000G a deep test is a real run-down to about 22 % charge. While it runs, the UPS's USB reports can freeze at "on mains, 100 %"; the page's Power-cycle UPS link button makes it report the truth again, and the page warns you before the test starts.
APC models
- Tested on the bench
- Back-UPS ES 600M1 (BE600M1)Back-UPS RS 1000GSmart-UPS X 1500
- Confirmed by a buyer
- Back-UPS RS 1350MS
- Checked with owner data
- Back-UPS 500Back-UPS BX1600MIBack-UPS ES 850G2Back-UPS ES 850M2Back-UPS XS 1400UBack-UPS XS 1500MSmart-UPS 1000Smart-UPS 1500 RMSmart-UPS 3000Smart-UPS SRT 3000 RMXLSmart-UPS X 750
- Should work
- APC AP9584 Serial-to-USB kitBack-UPS (USB)Back-UPS BF500Back-UPS BK****M2-CH Series (may need tweaks since 2023)Back-UPS BK650M2-CHBack-UPS BVK****M2 Series (may need tweaks)Back-UPS BX****MI Series (may need tweaks since 2023)Back-UPS CS USBBack-UPS ES/CyberFort 350Back-UPS LS USBBack-UPS Pro USBBack-UPS RS USBBack-UPS XS 1000M (Back-UPS Pro 1000, Model BX1000M)BACK-UPS XS LCDCS500Smart-UPS (USB)Smart-UPS 1500 (SMT1500I, USB)Smart-UPS 750 (SMT750I, USB)SMC2200BI-BR
- Won't work
- Units with only a serial port or a network card, and most that speak a serial protocol over USB. The full compatibility list explains each level.
- Not listed?
- Most USB UPSes still work: the board reads each UPS's own description of itself, not this list. Ask us before you buy.
Connect it
- Home Assistant
- Settings → Devices & services → Add integration → Network UPS Tools (NUT). Host: the Pal's address. Port:
3493. Username and password are optional for reading; add the Pal's login if you want the self-test and beeper buttons. - Synology
- Control Panel → Hardware & Power → UPS. UPS type: Synology UPS server, server IP: the Pal's. Step-by-step guide.
- TrueNAS
- System Settings → Services → UPS. UPS Mode: Slave, Remote Host: the Pal's IP, Remote Port:
3493, Identifier:ups. - unraid
- The NUT plugin in slave mode, pointed at the Pal's address on port
3493, UPS nameups. - Proxmox and Linux
- Install
nut-clientand add one line toupsmon.conf:MONITOR ups@ups-esp32-XXXX.local 1 user pass secondary(older NUT saysslave). Any username and password work for monitoring. - Other brands
- CyberPower · Eaton · Tripp Lite · All brands