CyberPower UPS with Home Assistant, Synology and NUT
Put your CyberPower UPS on the network with My UPS Pal: no Raspberry Pi, no network card. Here is what we know about CyberPower units.
What to expect
- On our bench
- The EC850LCD: full read, self-test, beeper, low-battery threshold and shutdown controls, and a real run-down to low battery.
- Readings
- On CyberPower's
0764:0501units the board applies the same corrections as NUT'scps-hiddriver: battery voltage and frequency are rescaled when the UPS reports them in odd units, and charge is capped at 100 %. - Deep test
- The EC850LCD has no deep test over USB. It runs its normal short self-test instead, so the page disables the deep-test button on this model and says why.
- Missing values
- The EC850LCD reports no input frequency, no instantaneous power and no battery date: the UPS itself doesn't have them. Other models may.
CyberPower models
- Tested on the bench
- EC850LCD
- Checked with owner data
- CP 1500CCP1000PFCLCDaCP1300EPFCLCDCP1500AVRLCDaCP1500PFCLCDCP900EPFCLCDOL1000EXLOR2200LCDRT2UOR600ERM1UPR3000ELCDSLST SeriesVP1600ELCD
- Should work
- AE550BL1250UBR1000ELCDCP1000PFCLCDCP1350AVRLCDCP1350EPFCLCDCP1350PFCLCDCP1500AVRLCDCP1500EPFCLCDCP825AVR-G / LE825GCP850PFCLCDCP900AVRCPJ500CPS685AVRCPS800AVREC350GEC750GOR1500ERM1UOR2200LCDRM2UOR500LCDRM1UOR700LCDRM1UPR1500RT2UPR6000LCDRTXL5URT650EIUT2200EValue 1500ELCD-RUValue 400EValue 600EValue 800EVP1200ELCD (ValueII_1200E)
- Won't work
- Units with only a serial port or a network card, and most that speak a serial protocol over USB. The full compatibility list explains each level.
- Not listed?
- Most USB UPSes still work: the board reads each UPS's own description of itself, not this list. Ask us before you buy.
Connect it
- Home Assistant
- Settings → Devices & services → Add integration → Network UPS Tools (NUT). Host: the Pal's address. Port:
3493. Username and password are optional for reading; add the Pal's login if you want the self-test and beeper buttons. - Synology
- Control Panel → Hardware & Power → UPS. UPS type: Synology UPS server, server IP: the Pal's. Step-by-step guide.
- TrueNAS
- System Settings → Services → UPS. UPS Mode: Slave, Remote Host: the Pal's IP, Remote Port:
3493, Identifier:ups. - unraid
- The NUT plugin in slave mode, pointed at the Pal's address on port
3493, UPS nameups. - Proxmox and Linux
- Install
nut-clientand add one line toupsmon.conf:MONITOR ups@ups-esp32-XXXX.local 1 user pass secondary(older NUT saysslave). Any username and password work for monitoring. - Other brands